Zeile 1: Zeile 1:
 ~~NOTOC~~ ~~NOTOC~~
-====== DVD-Drive-Based Laser Scanning Microscope ====== +====== DVD-Drive based Laser Scanning Microscope ====== 
-{{ :projekte:dvdlsm:dvdlsm_full.jpg?400|}}+{{ :projekte:dvdlsm:dvdlsm_full.jpg?450|}}
  
 Due to an abundance of one specific type of DVD drives, plans were made to give a useful afterlife to these devices. A laser scanning microscope seemed to be the most useful project. Due to an abundance of one specific type of DVD drives, plans were made to give a useful afterlife to these devices. A laser scanning microscope seemed to be the most useful project.
Zeile 29: Zeile 29:
  
 ==== Laser Diodes, Lens and Actuators ==== ==== Laser Diodes, Lens and Actuators ====
-The OPU houses two laser diodes. As this is just a DVD/CD reader, the lasers are not very powerful but provide sufficient power for microscopic applications. The (red) DVD diode starts laser operation above approx. 60 mA and requires about 2-2.5 V of forward voltage. Its polarity can be easily determined by measurements.+The OPU houses two laser diodes. As this is just a DVD/CD reader, the lasers are not very powerful but provide sufficient power for microscopy applications. The (red) DVD diode starts laser operation above approx. 60 mA and requires about 2-2.5 V of forward voltage. Its polarity can be easily determined by measurements.
  
 The primary lens is positioned using electromagnetic actuators. These come in the form of three coils, which tilt or move the coil proportionally to the current flowing though them. Their polarity and required full-scale DC actuation current can be easily found by using a lab power supply. The primary lens is positioned using electromagnetic actuators. These come in the form of three coils, which tilt or move the coil proportionally to the current flowing though them. Their polarity and required full-scale DC actuation current can be easily found by using a lab power supply.
Zeile 59: Zeile 59:
 It was conjectured that the smaller inner quadrants were responsible for the low-sensitivity outputs, while the outer segments would produce a large amplitude (due to their larger light collection area). It was conjectured that the smaller inner quadrants were responsible for the low-sensitivity outputs, while the outer segments would produce a large amplitude (due to their larger light collection area).
  
-In a second reverse engineering session, the exact pinout was determined by means of selective illumination: For a given test, two IC output pins were compared using two DVMs, and an aperture was slowly moved along the surface, either vertically or horizontally. This would in a change of the output voltage for one of the outputs slightly earlier than for the other one. In this way, the positional relationships between all output pins could be resolved, forming a final assignment of diode quadrants to output pins.+In a second reverse engineering session, the exact pinout was determined by means of selective illumination: For a given test, two IC output pins were compared using two DVMs, and an aperture was slowly moved along the surface, either vertically or horizontally. This would in result a change of the output voltage for one of the outputs slightly earlier than for the other one. In this way, the positional relationships between all output pins could be resolved, forming a final assignment of diode quadrants to output pins.
  
 {{:projekte:dvdlsm:pinout_bg.png?800|}} {{:projekte:dvdlsm:pinout_bg.png?800|}}
Zeile 153: Zeile 153:
  
  
-Scan of an I2C test chip from my colleage Szymon (fabricated in 65nm CMOS, picture below). Scan area 1x1mm.+Scan of an I2C test chip from my colleague Szymon (fabricated in 65nm CMOS, picture below). Scan area 1x1mm.
  
 {{:projekte:dvdlsm:i2chip_first_scan_dt.jpg?600|}} {{:projekte:dvdlsm:i2chip_first_scan_dt.jpg?600|}}
Zeile 162: Zeile 162:
  
 {{:projekte:dvdlsm:i2chip_fill_200nm.png?600|}}  {{:projekte:dvdlsm:i2chip_fill_200nm.png?600|}} 
 +
 +
 +Finally, here are two videos of the device in Action:
 +  * Focusing: https://youtu.be/iFzVEHeG0xE
 +  * Scanning: https://youtu.be/cj5zdhJTQUs
  
 ===== Summary ===== ===== Summary =====
Zeile 169: Zeile 174:
   * PC software: https://git.loetlabor-jena.de/dvdlaser/dvdlaser_sw   * PC software: https://git.loetlabor-jena.de/dvdlaser/dvdlaser_sw
  
- +===== References ===== 
 +I'm of course not the first one to build something like this. Here's some sources of my own inspiration: 
 +  * http://www.gaudi.ch/GaudiLabs/?page_id=652 
 +  * https://www.instructables.com/Laser-Scanning-Microscope/ 
 +  * https://pubs.acs.org/doi/10.1021/acssensors.8b00340 
 +  * https://www.researchgate.net/publication/321233124_Generating_SEL_and_SEU_with_a_class_1_laser_setup
  
  